MicroBooNE Document 1744-v1

Estimation of Max. Temperature for Ar Gas Exiting Ullage Space in Micro-Boone

Document #:
MicroBooNE-doc-1744-v1
Document type:
Design or Technical Note
Submitted by:
KC Wu
Updated by:
KC Wu
Document Created:
02 Nov 2011, 12:57
Contents Revised:
02 Nov 2011, 12:57
Metadata Revised:
02 Nov 2011, 12:57
Viewable by:
  • Public document
Modifiable by:

Quick Links:
Latest Version

Abstract:
Using energy balance and heat transfer equation, temperatures of argon exiting ullage space have been estimated for Micro-Boone. For the 3 cases under consideration, the temperatures are 178K, 176K and 150K. Note, this study is not applicable to nozzles and feedthrough on the vessel where temperautres are higher because top of nozzles is near ambient temperature. Temperature profile inside nozzles will be investigated in another note.
Files in Document:
Other Files:
Authors:
Notes and Changes:
This documentation is submitted under WBS 1-10. However, it is also of interest to subjects such as liquid argon heat transfer, thermal evaluation of feedthrough and outgassing study.